SP3000 HV & MV Power Cable Fault Monitoring & Diagnosis

The SP3000 Cable Monitoring System is a cutting-edge platform for real-time fault diagnosis, early warning, and precise location of issues within high-voltage and medium-voltage power cable networks. Designed to ensure grid reliability, it addresses challenges such as undetectable insulation aging, hidden discharge, and fault current tracing with accuracy up to 0.2% × cable length + 5m.

Share This Product :

The SP3000 Cable Monitoring System is a cutting-edge platform for real-time fault diagnosis, early warning, and precise location of issues within high-voltage and medium-voltage power cable networks. Designed to ensure grid reliability, it addresses challenges such as undetectable insulation aging, hidden discharge, and fault current tracing with accuracy up to 0.2% × cable length + 5m.
  • Real-time monitoring of cable discharge events (traveling wave-based)
  • Ultra-wide sensor bandwidth:

Current: 0.1kHz–10MHz

Traveling wave: 1kHz–20MHz

  • Fault positioning accuracy: ≤0.2% × L + 5m
  • Simultaneous early warning + fault classification
Technical Specifications
Parameter Value
Sensor Bandwidth (Current) 0.1kHz–10MHz
Sensor Bandwidth (Traveling Wave) 1kHz–20MHz
Measurement Range 1mA – 10kA
Working Voltage DC ±35kV to ±1100kV / AC 10kV to 1000kV
Power Supply Coupling + Solar + Mains
Protection Level IP66
Operating Temp -40°C to +250°C
Humidity 1%–100% RH
Altitude Range ≤5000m
Communication Wired/Wireless (Supports Internet, GPRS, SMS Alerts)
Standards IEC, CMA, CNAS
Installation Guidelines
  • 1 cable MT set = 1 data acquisition unit + 9 sensors
  • For cable lines ≤10km: install 1 set at each end
  • For >10km: add 1 set every 10km + each long branch
  • Supports hybrid systems (overhead & cable integration)
 Functional Highlights
  • 01. Section Position Identification Pinpoints the fault section even in complex/mixed lines to clarify unit responsibility.
  • 02. Fault Location Uses traveling wave polarity + amplitude for exact fault pinpointing (within 5m accuracy).
  • 03. Early Warning System Detects abnormal discharges before they escalate into trips, enabling predictive maintenance.
  • 04. Multi-loop Monitoring Supports up to 12 cables simultaneously, enabling large-scale system integration.
  • 05. AI Visual Integration (Optional) Snapshots fault conditions in real-time and automatically alerts operators via the backend.
Advanced Detection Capabilities
  • Vegetation interaction
  • Floating objects
  • External damage or illegal construction
  • Icing & pollution discharge
  • Wildlife interference
  • Tower/insulator degradation
Smart Platform Integration
  • Compatible with SCADA, Data Center, or cloud dashboards
  • Allows SMS/Internet alerts + Web interface
  • Supports 24/7 condition-based monitoring
Use Cases & Applications
  • Underground HV/MV cable lines
  • Mixed network systems (overhead + cable)
  • Substation exit lines
  • Tunnel cable networks
  • Distribution grid monitoring
About Manufacturer:
Wuhan Sunshine Power Science & Technology Co., Ltd. was established in 2007 and has since become a leading innovator in the field of fault detection and early warning technologies for power grids. Based in Wuhan, China, the company specializes in the development and production of advanced systems such as the SP3000 Transmission Line Fault Early Warning and Diagnosis System. With over 80,000 installations worldwide and a market-leading presence in high-voltage fault monitoring, Sunshine Power has revolutionized the industry with their state-of-the-art technology. Their commitment to research and development has earned them multiple patents and national awards, making them a trusted partner for power grid operators around the globe. The company is dedicated to providing reliable, scalable, and energy-efficient solutions for fault detection across all levels of power transmission networks. The SP3000 system is installed on over 12,000 transmission circuits, covering 900,000+ kilometers of power lines and diagnosing over 12,000 faults. The system has achieved multiple patents and has been recognized with China national and provincial awards.