Protection & Safety Devices

MR Buchholz Relay Type 11-NO

Reinhausen (MR, Germany) Buchholz relay type 11-NO for liquid-filled transformers with conservator — gas alarm and oil surge trip. Second-hand unit.

Share This Product :

A Reinhausen (MR) Buchholz relay, type 11-NO, fitted in the pipe between the main tank and conservator of an oil-filled transformer.

What it detects, and why it detects it first

The Buchholz relay is the only device that sees an internal transformer fault while it is still developing. Every other protection — differential, overcurrent, earth fault — responds once the fault has become an electrical event. The Buchholz responds to the gas that a fault produces before it gets there.

  • Gas accumulation → alarm. Partial discharge, local overheating or a developing turn-to-turn fault decomposes oil and paper into gas. It collects in the relay chamber, displaces the oil, and the upper float sinks to close the alarm contact.
  • Oil surge → trip. A high-energy internal fault gasifies oil violently and drives a surge toward the conservator. The flap operates and trips the transformer within the first cycles.
  • Loss of oil → trip. A serious leak drops the oil level and the same element operates.

The gas is evidence, not just a signal

Gas collected in the relay chamber can be drawn off and analysed. Hydrogen and methane indicate partial discharge or low-energy faults; ethylene and acetylene indicate high-energy arcing. A Buchholz alarm therefore hands the engineer a sample of the fault itself — which is why the alarm should never simply be reset without taking the gas.

Condition: second-hand unit. The constraint on any replacement is the pipe nominal diameter and flange pattern, not the electrical rating. Send a photograph of the existing relay and its type plate.

No additional information.

Need a quotation for this product?

Send us your specification and we route the enquiry straight to the manufacturer’s export team. Requesting a quotation through IndusGrove is free.

Independent listing. IndusGrove is an independent B2B directory for the power, electrical and renewable energy industry. We are not a distributor, agent or authorised reseller for the manufacturers listed here, and we do not hold stock. Manufacturer names, brand names, model numbers and trademarks are the property of their respective owners and appear here for identification and reference only.

Product information is compiled from publicly available manufacturer sources and may change without notice. Verify all specifications, ratings and compliance data with the manufacturer before purchase. Enquiries submitted through this page are referred to the manufacturer or its authorised channel.

Manufacturers may request an amendment or the removal of any listing at [email protected].