Dry Type Transformers

Wujiang Dry-Type Power Transformer (10 kV / 35 kV)

Cast resin and VPI dry-type transformers at 10 kV and 35 kV for indoor installations where oil is unacceptable — hospitals, data centres, high-rise buildings, tunnels, offshore platforms and rail transit.

Share This Product :

Wujiang Dry-Type Power Transformer (10 kV / 35 kV)

Dry-type transformers replace insulating oil with air and solid insulation, removing the fire load and the containment, bunding and fire-suppression requirements that come with an oil-filled unit. That makes them the default choice wherever a transformer has to sit inside an occupied building or a confined space. Wujiang Transformer produces dry-type units at 10 kV and 35 kV on dedicated production lines.

Why Dry-Type

  • No fire load, no oil containment. Nothing to leak, bund or extinguish; F1 flammability class units self-extinguish.
  • Installable indoors and close to load. Shorter LV runs, lower cable cost and lower losses.
  • Low maintenance. No oil sampling, no DGA, no gaskets or breathers to service.
  • Environmentally clean. No risk of soil or water contamination, which matters on tunnel, marine and protected-catchment projects.
  • Tolerant of humidity and pollution when specified with the appropriate enclosure and climatic class.

Typical Specification

  • Voltage class: 10 kV and 35 kV primary; LV to suit
  • Insulation: cast resin (epoxy) and vacuum pressure impregnated construction
  • Classes: environmental, climatic and fire behaviour classes to IEC 60076-11
  • Enclosure: open core-and-coil, or IP20 to IP54 sheet steel enclosure
  • Cooling: AN natural air, or AF forced air for uprated capacity
  • Options: winding temperature monitoring with fan control and alarm/trip contacts, anti-vibration mounts, cable boxes, busduct flanges
  • Standards: IEC 60076-11, GB, or the buyer’s specification

Applications

  • Hospitals, airports, shopping centres and other high-occupancy buildings
  • Data centres and telecom facilities
  • High-rise buildings and basement substations
  • Rail transit, metro and tunnel installations
  • Offshore platforms, marine and wind turbine nacelle duty
  • Petrochemical plant and other fire-sensitive process industries

Selection Notes

Dry-type transformers are less tolerant of sustained overload than oil-filled units, so the rating should reflect the real load profile rather than the connected load. Specify rated power, voltage ratio and tapping range, vector group, impedance, enclosure IP rating, ambient temperature and altitude, and whether forced-air uprating is required. Submit the enquiry through IndusGrove.

Designed and tested to IEC, ANSI/IEEE, GB and BS standards, or to the customer technical specification. Full type, routine and special testing available in-house, including sudden short-circuit testing. Contact via IndusGrove for capacity, voltage ratio, vector group and delivery.

Need a quotation for this product?

Send us your specification and we route the enquiry straight to the manufacturer’s export team. Requesting a quotation through IndusGrove is free.

Independent listing. IndusGrove is an independent B2B directory for the power, electrical and renewable energy industry. We are not a distributor, agent or authorised reseller for the manufacturers listed here, and we do not hold stock. Manufacturer names, brand names, model numbers and trademarks are the property of their respective owners and appear here for identification and reference only.

Product information is compiled from publicly available manufacturer sources and may change without notice. Verify all specifications, ratings and compliance data with the manufacturer before purchase. Enquiries submitted through this page are referred to the manufacturer or its authorised channel.