Transformer Bushings

Yash RIP Condenser Bushing (24 kV – 245 kV)

Resin impregnated paper condenser bushings from 24 kV to 245 kV. Dry, oil free, leakage proof and non-flammable, with a silicone housing option — the low maintenance choice for modern substations and for retrofitting ageing OIP units.

Share This Product :

Yash RIP Condenser Bushing (24 kV – 245 kV)

A resin impregnated paper (RIP) bushing replaces the oil in the condenser core with cured epoxy resin. The core is wound from crepe paper with grading foils, vacuum dried and impregnated with resin, then cured into a solid, void free body. The result is a completely dry bushing — nothing to leak, nothing to burn, and nothing to top up.

Why Utilities Are Moving to Dry Bushings

  • No oil, no leaks. Oil leakage at the flange is a routine maintenance burden on OIP populations and an environmental liability on sites near watercourses.
  • Non-flammable. Removing the oil removes the fuel. This is the decisive argument in indoor substations, underground installations, tunnels and offshore platforms.
  • Fails benignly. A dry core does not produce the pressure rise that turns an OIP bushing failure into a tank rupture and fire.
  • Low maintenance. No oil level to monitor, no sight glass, no gasket ageing.
  • Transport and storage. Can be shipped and stored horizontally without the handling restrictions oil filled bushings carry.
  • Silicone housing option. Combined with a dry core it gives the lightest, most pollution tolerant assembly available.

RIP and RIS

Yash supplies both RIP, using resin impregnated crepe paper, and RIS, using resin impregnated synthetic insulation. RIS replaces the cellulose with a synthetic material, further reducing moisture sensitivity during manufacture and in service. Both are supplied across the same 24 kV to 245 kV range and to the same standards; the choice usually comes down to the buyer’s own specification and the humidity of the installation.

Typical Specification

  • Voltage class: 24 kV to 245 kV
  • Insulation: resin impregnated paper (RIP) or resin impregnated synthetic (RIS) condenser core
  • Housing: silicone rubber or porcelain
  • Test tap: capacitance and tan delta tap fitted as standard
  • Standards: IEC 60137:2017 and equivalents
  • Options: BCT accommodation, custom creepage, custom oil end length, transformer or wall mounting

Applications

  • Indoor and underground substations where fire load must be minimised
  • Offshore platforms, marine and other confined installations
  • Retrofit of ageing OIP bushings on in-service transformers
  • Sites with environmental restrictions on oil
  • Networks pursuing lower lifetime maintenance cost

Ordering Information

Specify rated voltage and current, creepage requirement, housing material, mounting arrangement and BCT needs. For retrofit, state the make and model of the bushing being replaced — Yash has developed interchangeable OIP to RIP and OIP to RIS solutions that preserve the existing mounting and turret. Submit the enquiry through IndusGrove.

Type tested at ILAC accredited laboratories, with more than 140 standardised model type tests available. Supplied against IEC 60137:2017, IEEE C57.19.00/01 and equivalents. Retrofit and interchangeable solutions available for existing bushings of any global make. Contact via IndusGrove with voltage class, current rating, creepage and mounting details.

Need a quotation for this product?

Send us your specification and we route the enquiry straight to the manufacturer’s export team. Requesting a quotation through IndusGrove is free.

Independent listing. IndusGrove is an independent B2B directory for the power, electrical and renewable energy industry. We are not a distributor, agent or authorised reseller for the manufacturers listed here, and we do not hold stock. Manufacturer names, brand names, model numbers and trademarks are the property of their respective owners and appear here for identification and reference only.

Product information is compiled from publicly available manufacturer sources and may change without notice. Verify all specifications, ratings and compliance data with the manufacturer before purchase. Enquiries submitted through this page are referred to the manufacturer or its authorised channel.

Manufacturers may request an amendment or the removal of any listing at [email protected].