Transformer Bushings

Yash OIP High Current Bushing (5,000 A – 25,000 A)

High current OIP bushings for generator step-up transformer LV terminals, rated 5,000 A to 25,000 A in voltage classes from 24 kV to 52 kV. Built to IEC 60137:2017 and IEEE C57.19.00/01. 25,000 A is the highest rating supplied to date.

Share This Product :

Yash OIP High Current Bushing (5,000 A – 25,000 A)

On a generator step-up transformer the low voltage terminal carries the full machine output at generator voltage — typically 11 kV to 33 kV at many thousands of amperes. The bushing at that terminal is a different engineering problem from a high voltage bushing: the electrical stress is modest, but the thermal and electromagnetic duty is severe.

The Design Problem

Continuous currents in the tens of kiloamperes generate resistive heating in the central conductor and eddy current heating in every nearby metallic part, including the mounting flange and the transformer turret. Uncontrolled, that heat degrades the paper insulation and the transformer oil around it. High current bushing design therefore concentrates on conductor cross section and material, joint and clamping design at both ends, non-magnetic materials and shielding near the flange, and a thermal path that keeps hot spot temperatures within the insulation class under continuous full load. Short circuit forces at the terminals are also far higher than on a HV bushing, so mechanical strength governs the terminal design.

Typical Specification

  • Current rating: 5,000 A to 25,000 A to IEC; 6,000 A to 20,000 A to IEEE
  • Voltage class: 24 kV to 52 kV
  • Insulation: oil impregnated paper condenser core
  • Housing: glazed porcelain
  • Standards: IEC 60137:2017, IEEE C57.19.00 and C57.19.01, or equivalents
  • Options: bushing current transformer accommodation, custom terminal palm and busbar interface, custom flange and inclination

Applications

  • Generator step-up transformer LV terminals on thermal, hydro, nuclear and combined cycle plant
  • Unit auxiliary and station transformers on large generating units
  • Industrial furnace and rectifier transformers
  • Any oil filled apparatus with a high current, medium voltage terminal

Ordering Information

Specify rated continuous current and voltage class, governing standard, the busbar or flexible connection interface at the air end, oil end length and terminal arrangement, ambient and altitude conditions, and any BCT requirement. On replacement work, supply the existing drawing so the mounting and turret interface can be reproduced exactly. Submit the enquiry through IndusGrove.

Type tested at ILAC accredited laboratories, with more than 140 standardised model type tests available. Supplied against IEC 60137:2017, IEEE C57.19.00/01 and equivalents. Retrofit and interchangeable solutions available for existing bushings of any global make. Contact via IndusGrove with voltage class, current rating, creepage and mounting details.

Need a quotation for this product?

Send us your specification and we route the enquiry straight to the manufacturer’s export team. Requesting a quotation through IndusGrove is free.

Independent listing. IndusGrove is an independent B2B directory for the power, electrical and renewable energy industry. We are not a distributor, agent or authorised reseller for the manufacturers listed here, and we do not hold stock. Manufacturer names, brand names, model numbers and trademarks are the property of their respective owners and appear here for identification and reference only.

Product information is compiled from publicly available manufacturer sources and may change without notice. Verify all specifications, ratings and compliance data with the manufacturer before purchase. Enquiries submitted through this page are referred to the manufacturer or its authorised channel.

Manufacturers may request an amendment or the removal of any listing at [email protected].