Vacuum Circuit Breakers

Fuerte Vacuum Circuit Breaker (12 kV – 36 kV)

Medium voltage vacuum circuit breakers from 12 kV to 36 kV for indoor switchgear and outdoor pole-mounted duty. Vacuum interruption gives long contact life and effectively maintenance-free operation with no SF6.

Share This Product :

Fuerte Vacuum Circuit Breaker (12 kV – 36 kV)

A vacuum circuit breaker interrupts current by drawing the arc inside a sealed vacuum interrupter. With no gas to ionise, the arc extinguishes at the first current zero and dielectric strength recovers almost instantly. That physics gives the VCB its two defining commercial advantages: very long contact life and essentially no maintenance of the interrupting element.

Why Vacuum, and Why It Matters Now

  • No SF6. Sulphur hexafluoride is the most potent greenhouse gas in industrial use, and regulation is tightening in Europe and increasingly elsewhere. Vacuum sidesteps the issue entirely at medium voltage.
  • Contact life measured in thousands of operations, against tens or hundreds for oil breakers — decisive on capacitor bank and motor switching duty, and on automated networks that operate frequently.
  • Sealed for life. The interrupter needs no gas topping up, no oil changes and no internal inspection.
  • Compact. The short contact gap allows smaller panels and smaller substation buildings.

Typical Specification

  • Rated voltage: 12 kV, 24 kV, 33 kV, 36 kV
  • Rated current: typically 630 A to 1600 A, per design
  • Short circuit breaking current: to design rating; state the requirement with the enquiry
  • Configuration: indoor panel mounted or outdoor pole mounted
  • Operating mechanism: spring stored energy, motor charged, with electrical and manual close and trip
  • Options: auxiliary contacts, undervoltage and shunt trip coils, integral current transformers, protection relay interface
  • Standards: IEC 62271-100 and equivalents, or buyer specification

Applications

  • Primary and secondary distribution substations
  • Pole-mounted feeder switching and automation schemes
  • Industrial plant, motor and capacitor bank switching
  • Wind and solar collector substations
  • Replacement of ageing oil circuit breakers

Ordering Information

Specify rated voltage and continuous current, short circuit breaking and making current, indoor or outdoor, operating mechanism and control voltage, protection and metering interface, and the governing standard. State whether the breaker is to fit an existing panel, and supply the panel drawing if so. Submit the enquiry through IndusGrove.

ISO 9001 certified by DEKRA Germany, with products independently verified by CESI Italy and KEMA Netherlands. More than 100 bespoke designs delivered to customer grid codes. OEM and ODM supported. Contact via IndusGrove with system voltage, rating, standard and annual quantity.

Need a quotation for this product?

Send us your specification and we route the enquiry straight to the manufacturer’s export team. Requesting a quotation through IndusGrove is free.

Independent listing. IndusGrove is an independent B2B directory for the power, electrical and renewable energy industry. We are not a distributor, agent or authorised reseller for the manufacturers listed here, and we do not hold stock. Manufacturer names, brand names, model numbers and trademarks are the property of their respective owners and appear here for identification and reference only.