| Current Legal Name | Reinhausen GmbH — renamed 30 April 2026 |
|---|---|
| Former Name | Maschinenfabrik Reinhausen GmbH (MR) |
| Headquarters | Regensburg, Bavaria, Germany |
| Roots | 1868 — repair workshop in Sallern making frame saws |
| 1901 | Registered as Maschinenfabrik Reinhausen by Andreas Scheubeck |
| 1926 | Fundamental on-load tap changer patents; world's first high-speed resistor-type OLTC prototype, with Dr. Bernhard Jansen |
| Ownership | Family-owned across six generations |
| Scale | Approximately 5,500 employees; around EUR 1.5 billion revenue |
| Executive Management Spokesperson | Dr. Nicolas Maier-Scheubeck |
| Key Product Brands | OILTAP® · VACUTAP® · MESSKO® · TAPCON® |
| Core Range | On-load tap changers · De-energised tap changers · Voltage regulating controllers · Transformer monitoring and accessories |
Reinhausen — known throughout the industry as MR, and until April 2026 as Maschinenfabrik Reinhausen — is the company that invented the on-load tap changer and has led the field ever since. It is family-owned across six generations, based in Regensburg, Bavaria, and employs around 5,500 people.
In the 1920s, changing a transformer’s ratio meant taking it off the grid. As networks grew, that became untenable — utilities needed to regulate voltage continuously, under load, without interrupting supply.
Dr. Bernhard Jansen had the concept; Maschinenfabrik Reinhausen had the mechanical engineering to build it. The result, patented in 1926, was the world’s first prototype of a high-speed resistor-type tap changer for interruption-free switching under load. Nearly every regulated power transformer built since works on that principle. Jansen subsequently granted the Scheubeck brothers the right to produce tap changers for the German transformer industry.
The roots go back further than the tap changer. A repair workshop was founded in Sallern in 1868, making full and split-frame saws. Carl and Katharina Dänner bought it in 1891, and in 1901 Andreas Scheubeck registered it as Maschinenfabrik Reinhausen with the district court in Stadtamhof.
Exactly 125 years later, on 30 April 2026, the company shortened its name to Reinhausen GmbH — on the reasoning, as Executive Management Spokesperson Dr. Nicolas Maier-Scheubeck put it, that it had outgrown the “Maschinenfabrik” (machine factory) designation. Both names refer to the same company, and equipment in service will carry either.
The on-load tap changer is the only assembly in a power transformer with moving contacts that make and break current, and it may operate tens of thousands of times a year on a heavily regulated feeder. Statistically it is among the most failure-prone parts of the asset, and it is the reason a transformer needs its own protection relay on the diverter compartment as well as a Buchholz relay on the main tank.
That is also why the choice between an oil-type and a vacuum tap changer is an economic decision about the next thirty years, not just a technical one.