Share This Product :
| Feature | Specification |
| Model | ACR10RH-DxxT(R)E4 / E3 |
| Installation Type | DIN rail (guide rail) |
| Voltage Input | AC 57.7/100V or 220/380V (rated); 1.2× continuous, 2× for 1s |
| Current Input | Via open-type CT or Rogowski coil (80A to 20000A) |
| Frequency | 45–65Hz |
| Power Supply | AC 85–265V or DC 100–350V / DC 24V / DC 48V |
| Power Consumption | ≤10VA |
| Accuracy | Frequency: ±0.05Hz |
| Communication | RS485, Modbus-RTU protocol |
| Display | LCD with function keys (FN, SET, ▲, ▼, ENTER) |
| Digital Inputs (DI) | Up to 4 (dry contact) |
| Relay Outputs (DO) | Up to 2 (3A @ AC250V/DC30V) |
| Pulse Output | 2 channels (4000–8000 imp/kWh) |
| Harmonics | 2nd to 31st order; THD included |
| Event Logging (optional) | SOE (requires DI/DO configuration) |
| Max Demand Measurement | Supported |
| Environment | Temp: -10°C to +55°C (storage: -20°C to +70°C), RH: ≤95% non-condensing |
| Altitude | ≤2500m |
| Insulation Resistance | ≥100MΩ; Withstand voltage: AC 2kV (1 min) |
No additional information.