Neutral Grounding & Earthing Systems

Sieyuan Arc Suppression Coil (Petersen Coil)

  • Arc suppression coil (Petersen coil) for resonant earthed medium voltage networks, 6 kV to 66 kV.
  • Cancels the capacitive earth fault current so transient faults self-extinguish without a trip.
  • Continuously variable plunger core or tap changer type with automatic tuning controller.
  • Holds a defined detuning factor and tracks changing network capacitance as feeders switch.
  • Oil-immersed outdoor construction, optionally with a parallel resistor for permanent fault detection.
  • Paired with an earthing transformer where the network has no accessible neutral.

Share This Product :

Sieyuan Arc Suppression Coil (Petersen Coil)

An arc suppression coil is the alternative to resistance earthing, and it answers a different question. A resistor asks how to detect and clear an earth fault safely. A Petersen coil asks how to make the fault go away without tripping anything at all.

The Principle

Every network has distributed phase-to-earth capacitance, and on an unearthed system that capacitance is what feeds an earth fault. The fault current is capacitive and leads the driving voltage by 90 degrees. An arc suppression coil is a variable inductive reactor connected between the neutral and earth, tuned so its inductive current is equal and opposite to that capacitive current.

At the fault point the two components cancel. What remains is a small residual current, largely resistive and a few percent of the uncompensated value — too small to sustain an arc. The transient fault self-extinguishes at the first current zero and does not restrike, because the recovery voltage across the fault path rises slowly instead of jumping. The network keeps running through the fault.

This matters most on overhead distribution, where the great majority of earth faults are transient: a branch, a bird, a lightning flashover. On a resistance earthed network every one of those events is an outage. On a compensated network they pass without a trip.

Tuning

The compensation is only as good as the tuning, and network capacitance changes every time a feeder is switched. Modern installations therefore use a continuously variable coil — plunger core or on-load tap changer type — with an automatic tuning controller that measures the neutral displacement voltage, tracks the resonance point and holds a defined detuning factor. Running exactly at resonance is deliberately avoided: a small detuning keeps the healthy-phase neutral voltage displacement within limits and stops the network from resonating on an unbalance.

Construction and Ratings

  • Continuously variable inductance by plunger core or tap changer, with fixed-tap versions where network capacitance is stable
  • Automatic tuning controller with neutral displacement measurement and detuning factor control
  • Oil-immersed construction for outdoor substation service
  • Supplied with a parallel resistor switching scheme where the earthing philosophy requires a permanent fault to be converted to a detectable current for selective tripping
  • Applied on networks from 6 kV to 66 kV, sized against the total network capacitive earth fault current
  • Normally paired with an earthing transformer where the network is delta fed

Resistance or Resonance

Neither is universally correct. Choose resistance earthing where earth faults are mostly permanent cable failures, where selective tripping matters more than continuity, and where rotating machines must be protected from core damage — typical of industrial and cable networks. Choose resonant earthing where faults are mostly transient overhead events and continuity of supply is the priority. Many utilities run both, by network type. An earthing study on the actual zero sequence capacitance is what settles it, not a preference.

Ordering Information

State the system nominal voltage, the total network capacitive earth fault current or the cable and overhead line lengths from which it can be calculated, the expected future network growth, whether automatic tuning is required, indoor or outdoor installation, and whether a parallel resistor for permanent fault detection is wanted. Submit the enquiry through IndusGrove.

No additional information.

Need a quotation for this product?

Send us your specification and we route the enquiry straight to the manufacturer’s export team. Requesting a quotation through IndusGrove is free.

Independent listing. IndusGrove is an independent B2B directory for the power, electrical and renewable energy industry. We are not a distributor, agent or authorised reseller for the manufacturers listed here, and we do not hold stock. Manufacturer names, brand names, model numbers and trademarks are the property of their respective owners and appear here for identification and reference only.

Product information is compiled from publicly available manufacturer sources and may change without notice. Verify all specifications, ratings and compliance data with the manufacturer before purchase. Enquiries submitted through this page are referred to the manufacturer or its authorised channel.

Manufacturers may request an amendment or the removal of any listing at [email protected].