Neutral Grounding & Earthing Systems

Sieyuan Neutral Grounding Resistor (6 kV – 66 kV, 100 A – 2000 A)

  • Neutral grounding resistor for 6 kV to 66 kV distribution, generator and industrial networks.
  • Earth fault current 100 A to 2000 A, 10 second or continuous duty.
  • High-resistivity alloy element, 1390 °C melting point, 1100 °C maximum operating temperature.
  • Low temperature coefficient keeps resistance stable so earth fault protection stays sensitive.
  • Excellent oxidation resistance for polluted, coastal and high-humidity sites.
  • Available as a complete package with earthing transformer, neutral CT and protection relay.
  • CE certified. Supplied to utility and renewable projects in over 100 countries.

Share This Product :

Sieyuan Neutral Grounding Resistor (NGR / NER)

A neutral grounding resistor sets the earth fault current of a distribution network to a value the designer chooses, rather than a value the system impedance happens to produce. It is the single component that decides how a network behaves on its most common fault.

Why Resistance Earthing

An isolated or unearthed neutral looks safe because the fault current is small, but it is not. An intermittent arcing earth fault on an unearthed system charges and discharges the healthy phase capacitances, and the restriking arc drives transient overvoltages that can reach several times normal phase voltage. Those overvoltages find the weakest insulation on the network — usually a cable termination or an aged motor winding — and turn a single phase-to-earth fault into a phase-to-phase fault somewhere else entirely.

Resistance earthing removes that mechanism. The resistor injects a real (in-phase) current component that damps the arc, caps the transient overvoltage, and — just as important — produces enough measurable current for earth fault protection to see the fault and grade selectively. Solid earthing does that too, but at fault currents that damage the machine core, the cable and the switchgear. The resistor is the middle path: enough current to detect, not enough to destroy.

Sizing

The resistor is defined by the earth fault current the system needs, not by an ohmic value in a catalogue. For a 6.6 kV system the resistor sees the phase-to-neutral voltage, 6.6 / √3 = 3.81 kV, so a 200 A design works out at approximately 19 Ω. Time rating matters as much as the current: utility distribution neutrals are commonly rated 10 seconds, while generator and industrial neutrals are often specified continuous. A resistor sized for 10 s duty and then operated continuously will fail.

Technical Specifications

  • Voltage range: 6 kV to 66 kV
  • Current range: 100 A to 2000 A
  • Element material: high-resistivity alloy, melting point up to 1390 °C
  • Maximum operating temperature: 1100 °C
  • Temperature coefficient: low, so resistance stays stable through the fault and protection sensitivity is preserved
  • Oxidation resistance: retains performance at 1100 °C, suitable for heavily polluted and coastal environments
  • Mechanical: element retains toughness under rapid thermal cycling and does not fracture
  • Certification: CE
  • Duty classes: to IEEE Std 32 neutral grounding device ratings

Applications

  • 6.6 kV and 11 kV industrial and utility distribution neutrals
  • Generator neutral earthing in power plants and captive generation
  • Wind and solar plant collector systems and their earthing transformer neutrals
  • Petrochemical, cement, steel and mining networks where motor damage on earth fault is the dominant risk
  • Retrofit of unearthed or solidly earthed networks after an insulation failure investigation

Complete Neutral Earthing Package

Where the network is delta-connected and has no accessible neutral, the resistor cannot be installed on its own. A zig-zag or wye-delta earthing transformer creates the artificial neutral and the resistor is connected to it. Sieyuan supplies the earthing transformer, the resistor, the neutral current transformer and the protection relay as one coordinated package, which removes the interface risk of buying the pieces from three suppliers.

Reference: 33 kV earthing transformer and neutral grounding resistor supplied to Saudi PIF renewable energy projects.

Ordering Information

To receive a firm quotation, state the system nominal voltage, the required earth fault current and time rating (10 s or continuous), whether the neutral is directly accessible or an earthing transformer is required, the enclosure and IP rating, the site ambient temperature and altitude, and the governing standard. Where the specification calls for an oil-immersed or hazardous-area construction rather than the standard ventilated enclosure, state it in the enquiry so it can be confirmed with the factory. Submit the enquiry through IndusGrove.

No additional information.

Need a quotation for this product?

Send us your specification and we route the enquiry straight to the manufacturer’s export team. Requesting a quotation through IndusGrove is free.

Independent listing. IndusGrove is an independent B2B directory for the power, electrical and renewable energy industry. We are not a distributor, agent or authorised reseller for the manufacturers listed here, and we do not hold stock. Manufacturer names, brand names, model numbers and trademarks are the property of their respective owners and appear here for identification and reference only.

Product information is compiled from publicly available manufacturer sources and may change without notice. Verify all specifications, ratings and compliance data with the manufacturer before purchase. Enquiries submitted through this page are referred to the manufacturer or its authorised channel.

Manufacturers may request an amendment or the removal of any listing at info@indusgrove.com.