Neutral Grounding & Earthing Systems

Trafo Elettro Oil-Immersed Earthing Transformer with Neutral Earthing Resistor

  • Oil-immersed earthing transformer supplied with a matched neutral earthing resistor (NER) as one design.
  • Zig-zag or wye-delta winding creating an artificial neutral on delta-fed 6.6 kV to 33 kV networks.
  • Sealed oil construction for coastal, desert and heavily polluted outdoor substations.
  • 10 second or continuous neutral duty, hermetic tank or conservator with dehydrating breather.
  • Built to customer specification — oil-immersed transformers to 50 MVA and 145 kV insulation class.
  • Italian manufacture since 1969, Montecchio Maggiore, Vicenza. EU origin.

Share This Product :

Trafo Elettro Oil-Immersed Earthing Transformer with Neutral Earthing Resistor

Where a specification calls for an oil-immersed neutral earthing arrangement rather than a ventilated resistor cabinet, the practical answer is an oil-immersed earthing transformer with the neutral earthing resistor supplied as part of the same design. Trafo Elettro has built special transformers to customer specification in Montecchio Maggiore, Vicenza since 1969.

Why Oil-Immersed

An outdoor ventilated resistor enclosure has to survive whatever the site does to it. On coastal, desert and heavy-industry sites the failure mode is not electrical — it is salt, dust and condensation attacking the element supports and insulators until creepage distance is gone. Oil-immersed construction closes the enclosure completely: the active parts sit in mineral oil, the dielectric strength is set by the oil rather than by an air gap that pollution keeps shrinking, and thermal behaviour under a repeated 10 second fault duty is far more predictable because oil carries heat away from the winding faster than natural convection in air.

The trade is maintenance. Oil needs sampling, and a sealed hermetic tank or a conservator with a dehydrating breather has to be chosen deliberately. On a unit that will sit untouched in a substation for thirty years, that choice is worth making at the enquiry stage rather than at commissioning.

Configuration

  • Zig-zag or wye-delta earthing winding creating an artificial neutral on a delta-fed network
  • Neutral earthing resistor connected to the created neutral, sized to the required earth fault current — for a 6.6 kV system the resistor works against 3.81 kV phase-to-neutral
  • Short time rating matched to protection clearing time, commonly 10 seconds, or continuous where the earthing philosophy requires it
  • Hermetically sealed tank or conservator with dehydrating breather
  • Auxiliary supply winding available where the same unit is to feed station services
  • Neutral current transformer and earth fault protection supplied on request
  • Outdoor installation, IP-rated marshalling box, oil and winding temperature monitoring

Manufacturer Capability

  • Oil-immersed transformers to 50 MVA, insulation class to 145 kV
  • Special transformer range: earthing, furnace, converter, excitation and rectifier transformers
  • Also cast resin, dry type and amorphous core distribution transformers
  • Built to customer specification rather than from a fixed catalogue — the normal route for neutral earthing equipment, which is almost never a standard item
  • Italian manufacture, EU origin documentation, IEC design and testing

Applications

  • 6.6 kV and 11 kV industrial plant neutrals where an oil-immersed construction is specified
  • Outdoor substations in coastal, desert and heavily polluted environments
  • Steel, cement, petrochemical and mining networks fed from delta windings
  • Renewable collector substations requiring a defined earth reference and EU-origin equipment
  • Replacement of a failed or undersized existing earthing transformer and resistor set

Ordering Information

State the system nominal voltage and frequency, the earth fault current and time rating required, the winding configuration if already fixed by the earthing study, whether a hermetic tank or conservator is wanted, any auxiliary load, the site ambient and pollution class, and the governing standard. If an earthing study has been done, sending it will get you a firmer quotation faster than a specification sheet will. Submit the enquiry through IndusGrove.

No additional information.

Need a quotation for this product?

Send us your specification and we route the enquiry straight to the manufacturer’s export team. Requesting a quotation through IndusGrove is free.

Independent listing. IndusGrove is an independent B2B directory for the power, electrical and renewable energy industry. We are not a distributor, agent or authorised reseller for the manufacturers listed here, and we do not hold stock. Manufacturer names, brand names, model numbers and trademarks are the property of their respective owners and appear here for identification and reference only.

Product information is compiled from publicly available manufacturer sources and may change without notice. Verify all specifications, ratings and compliance data with the manufacturer before purchase. Enquiries submitted through this page are referred to the manufacturer or its authorised channel.

Manufacturers may request an amendment or the removal of any listing at [email protected].