Transformer Bushings

Yash OIP Oil-to-Oil Bushing (24 kV – 245 kV)

Oil-to-oil OIP bushings from 24 kV to 245 kV for transformer cable box installations, where both ends of the bushing sit in oil rather than air. Fully customisable to the cable box geometry.

Share This Product :

Yash OIP Oil-to-Oil Bushing (24 kV – 245 kV)

An oil-to-oil bushing has oil on both sides instead of oil on one side and air on the other. It is used where a transformer connects into an oil filled cable box or a separate oil filled compartment, so the conductor never emerges into air at all. Removing the air interface removes the surface that pollution, moisture and wildlife can act on — which is precisely why this arrangement is chosen for heavily polluted, coastal and desert sites and for compact installations with no room for an air clearance.

Why the Design Differs

Because there is no air end, the external insulation and creepage requirements that dominate a conventional bushing disappear. What replaces them is a tighter set of dimensional and sealing constraints: the bushing must fit the cable box, seal reliably against two separate oil systems, and keep the two oil volumes isolated so that a fault or contamination in the cable box cannot migrate into the transformer tank. Radial clearances inside the box are usually the binding constraint, which is why these are almost always made to the customer’s drawing rather than selected from a catalogue.

Typical Specification

  • Voltage class: 24 kV to 245 kV
  • Insulation: oil impregnated paper condenser core
  • Configuration: oil to oil, for transformer cable box and compartment installations
  • Standards: IEC 60137:2017 and equivalents
  • Customisation: extensive — overall length, oil end lengths both sides, flange, sealing arrangement and terminals to the cable box drawing

Applications

  • Transformer to cable box connections on distribution and power transformers
  • Compact and indoor substations with restricted clearances
  • Coastal, desert and heavily polluted sites where an exposed air end is a liability
  • Installations where wildlife contact on exposed terminals is a recurring outage cause

Ordering Information

Supply the cable box drawing or the internal dimensions, rated voltage and current, required lengths on each side, flange and sealing details, and the terminal arrangement at both ends. Where an existing bushing is being replaced, the old drawing or a site measurement is the fastest route to an exact fit. Submit the enquiry through IndusGrove.

Type tested at ILAC accredited laboratories, with more than 140 standardised model type tests available. Supplied against IEC 60137:2017, IEEE C57.19.00/01 and equivalents. Retrofit and interchangeable solutions available for existing bushings of any global make. Contact via IndusGrove with voltage class, current rating, creepage and mounting details.

Need a quotation for this product?

Send us your specification and we route the enquiry straight to the manufacturer’s export team. Requesting a quotation through IndusGrove is free.

Independent listing. IndusGrove is an independent B2B directory for the power, electrical and renewable energy industry. We are not a distributor, agent or authorised reseller for the manufacturers listed here, and we do not hold stock. Manufacturer names, brand names, model numbers and trademarks are the property of their respective owners and appear here for identification and reference only.

Product information is compiled from publicly available manufacturer sources and may change without notice. Verify all specifications, ratings and compliance data with the manufacturer before purchase. Enquiries submitted through this page are referred to the manufacturer or its authorised channel.

Manufacturers may request an amendment or the removal of any listing at [email protected].